Relief valves for inline, subplate and cartridge mounting. Settings up to 350 bar, flows up to 160 L/min direct-acting and 400 L/min pilot-operated.

CXR valves open to tank when pressure reaches the setting, protecting pumps, hoses and actuators. Direct-acting versions respond in milliseconds. Pilot-operated versions give a flat pressure curve at high flow.
| Parameter | CXR direct-acting | CXR pilot-operated |
|---|---|---|
| Max setting | 350 bar | 350 bar |
| Max flow | 160 L/min | 400 L/min |
| Mounting | Inline, subplate, cartridge | Inline, subplate, cartridge |
| Adjustment | Screw with lock nut, optional knob | Screw with lock nut, optional knob |
| Fluid | Mineral oil HL / HLP, DIN 51524 | Mineral oil HL / HLP, DIN 51524 |
| Fluid temperature | −20 °C to +80 °C | −20 °C to +80 °C |
| Cleanliness | ISO 4406 20/18/15 | ISO 4406 20/18/15 |
| Cartridge cavities | SAE-08 / 10 / 12, M20 | SAE-10 / 12 |
Example: pilot-operated subplate relief valve, 210 to 350 bar range.
Use direct-acting valves as cross-line or safety relief. Move to pilot-operated when flow passes about 100 L/min.
Set the valve 10 to 15 percent above working pressure to avoid cracking open in normal service.
Pipe the tank port to a low-pressure return. Back pressure adds directly to the set point on direct-acting valves.
Main relief on excavators and loaders, pump protection in hydraulic power units, press circuits, and secondary relief on cylinder lines.


Give a branch its own lower pressure.

Relief cartridges for manifold blocks.

Relief valves built into a block to your drawing.
Unsure which valve you need? Read Relief Valve vs Pressure Reducing Valve.
Standard CXR valves ship without a minimum order quantity.